PAGE 14 INSERT INSTALLATION - For Qualified Installers Only!
Installation Preparation
! Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
! This appliance must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1
and NFPA 54(88).
! In Manufactured or Mobile Homes must confirm with: In USA, Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280; In Canada, CSA Z240.4 and Gas-Equipped
Recreational Vehicles and Mobile Housing. This appliance may be installed in Manufactured
Housing only after the home is site located.
! This appliance is designed to operate on natural gas, but may be converted to propane (LP).
! All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn
from outside the living-area structure.
! Notify your insurance company before hooking up this heater.
! The requirements listed below are divided into sections. All requirements must be met
simultaneously.
Items Required for Installation
¥ Insert Direct Vent Adapter (Travis Ind. Part # 98900122)
¥ Simpson Dura-Vent Adapter & Silicone (Part # 923GK)
¥ Simpson Dura-Vent Vertical Cap (Part # 991)
¥ Surround Panels (see page 33)
¥ Gas Hookup Equipment
Items Packed with the Chelan DV (700 DV)
¥ Chelan DV (with black or brass door)
¥ Propane Conversion Kit
¥ Owner's Manual
¥ Log Set (2 Logs, 2 Twigs, Embers)
Order of Installation
1 If the heater is to use propane, install the propane
conversion kit (see pages 37 - 42)
2 Re-route the power cord (if desired - see below)
3 Position the heater (see "Heater Placement")
4 Connect the gas line. Connect the gas vent.
5 Follow the instructions under "Finalizing the
Installation" on pages 20 and 21.
6 Install the surround panel kit.
Re-Routing the Power Cord to the Front
The power cord may be re-routed to the front of the heater if desired (see the directions below).
1 Disconnect the strain relief at the rear of the heater.
Strain Relief
Power Cord
Compress the strain relief
from the top and bottom
with a pair of slip joint
pliers. Once compressed,
the strain relief can be
pulled out.
TO REMOVE THE STRAIN RELIEF
Compress the strain relief
from the top and bottom
and insert it into the hole
until it locks in place.
TO INSTALL THE
STRAIN RELIEF
Seitenansicht 13