Avalon 700 Spezifikationen Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
ADDENDUM PAGE 39
ADDENDUM #1 Altitude Considerations
This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing
we have found that the fireplace, with its standard orifice, burns correctly with just an air shutter
adjustment. For information on adjusting the air shutter see page 21 of this manual.
! Failure to adjust the air shutter properly may lead to improper combustion which can create a
safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.
ADDENDUM #2 Class A Chimney Conversion Kit
Simpson Duravent provides a conversion kit for those wishing to use
an existing wood stove chimney to vent this direct vent stove. The
illustration below gives an overview of this type of installation. See
the instructions included with the kit for details.
! The conversion kit does not work on interior masonry chimneys.
! Do not exceed the maximum vertical rise (see the section
"Approved Vent Configurations" starting on page 9) allowable.
Remember to set the restrictor position to the correct position
(based upon the vertical rise height - see the chart on page 10).
Chimney Conversion Kit A (# 931)
Metalbestos 6" (150 mm) I.D.
Security Chimneys 6" (150 mm) I.D.
Jackes-Evans 6" (150 mm) I.D.
Hart & Cooley 6" (150 mm) I.D.
Pro-Jet 6" (150 mm) I.D.
Chimney Conversion Kit B (# 932)
Simpson Dura-Vent 6"(150 mm) I.D.
Air-Jet 6" (150 mm) I.D.
Metal-Fab 6" (150 mm) and 7" (175 mm) I.D.
Amer. Metals 6" (150 mm) & 7" (175 mm) I.D.
Metalbestos 7" (175 mm) and 8" (200 mm) I.D.
Jackes-Evans 7" (175 mm) and 8" (200 mm) I.D.
Hart & Cooley 7" (175 mm) and 8" (200 mm) I.D.
Pro-Jet 7" (175 mm) and 8" (200 mm) I.D.
Security Chimneys 8" (200 mm) I.D.
Chimney Conversion Kit C (# 933)
Simpson Dura-Vent 7" (175 mm) and 8" (200 mm) I.D.
American Metals 8" (200 mm) I.D.
Air-Jet 8" (200 mm) I.D.
Metal-Fab 8" (200 mm) I.D.
American Metals 8" (200 mm) I.D.
Each Kit Contains: Additional Equipment:
Retro Connector 4" Flex (#711 or U.L. 1777)
Retro Vertical Top Termination (#991)
Co-Axial Sections
Type A Chimney
Simpson Duravent Direct
Vent Pipe Sections
(use adjustable section)
Screw the Retro
Vertical Top to the
Flex Pipe
Retro Vertical Top
(screw to chimney)
Screw the Retro
Connector to the
Flex Pipe
Retro Connector
(screw to chimney)
4" (100 mm)
Aluminum Flex
Pipe
Cut the Flex Pipe to
the chimney height
plus 3" (75 mm)
ADDENDUM #3 Interior
Masonry Chimney Conversions
¥ Follow the requirements and use the
equipment listed in the illustration to
the right to install this appliance into
an interior masonry chimney.
¥ Maximum vertical rise is 30'
¥ Minimum vertical rise is 10'
¥ Use the following restrictor positions:
Position 7 for heights between 10' (3
M) and 24' (7.3 M)
Position 5 for heights between 24' (7.3
M) and 30' (9.1 M)
NOTE: these restrictor positions are
based upon lab tests. The ideal
restrictor position may vary slightly.
The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.
#711 Flex Liner
(4Ó dia.)
(or other UL 1777
Gas Liner)
Co-Axial
Straight
Lengths
#991 High
Wind
Termination
#990 90¡ Elbow
Flashing
(included in
#934 Masonry
Conversion Kit
Make sure the coaxial pipe
maintains a 1Ó clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
Connector with
Cover (included
in #934
Masonry
Conversion Kit
Seitenansicht 38